Model:
CD102
Power supply:
AC220V / 24VDC / 380VAC
Operating temperature:
0-50℃
Dimension:
87*57*91cm
Accuracy of Measurement:
±0.5%
Outline Dimension:
48*48mm
Overview of the CD series temperature controller CD101
CD series temperature controller instruments are intelligent double-row four-digit display instruments, which display measured values and set values respectively. They can input a variety of signals. The instrument is equipped with four-button operation, easy parameter setting and convenient input of information. The control method have two-position control and PID control. The instrument adopts super anti-interference chip design and the quality is reliable.
Characteristics of the CD series temperature controller CD101
1) Multi type signals input;
2) PID control,error correction;
3) Auto-Tuning;
4) Multiple alarm modes;
5) Optional positive-Negative of PID;
6) Parameter lock to avoid improper operation;
7) Used for industrial machinery,machine tools,measuring instruments.
The control modes of the CD series temperature controller CD101
The control modes of the CD series temperature controller CD101 have PID control and position control (also known as the hysteresis control or the upper and lower limit control). The PID control is a professional control method suitable for industrial control situations requiring high precision measurement control. PID is the abbreviation for proportion, integral, and differential. PID control combined the advantages of the three and have the function of timely and rapid proportion action, the ability to eliminate residuals with integral action, and the advanced control function of differential action. In addition, the self-tuning function of the meter can automatically calculate the optimal P.I.D. parameter value according to the control effect of the controlled object and automatically save it.
This series instruments are also with high cost performance.
lled object and automatically save it.
This series instruments are also with high cost performance.
Tecspecs:
Type | CD102 |
Power Supply | AC220V / 24VDC / 380VAC |
Input | Multi-input – K (-50~+ 1300℃), E(0~800℃), Cu50(-50~+150℃),PT100(-200~+600) |
Output | Double output(relay and SSR) / 4~20mA / 0-10V |
Accuracy of Measurement | ±0.5% |
Outline Dimension | 48*48mm |
Install Dimension | 45*45mm |
Operating temperature | 0-50℃ |
Compensating error of cold side | ±2℃(the software corrects the data for 0-50℃ fluctuations in temperature ) |
Control Mode | Adopt industrial and PID Parameters of Control System, Temperature Control, responsible faster, Start modulation smaller, accuracy higher than troditionalPID |
Type | CD series Temperature Controller |
Panel size | CD101 48x48mm CD401 48x96mm CD701 72x72mm CD501 96x48mm CD901 96x96mm |
Power supply | 85~265VAC 50~60Hz or 24VDC |
Accuracy | ±0.5F.S |
Control method | PID Control (with auto-tuning) or Self-tuning, or ON/OFF |
Sampling period | 0.5s |
Input type | TC, RTD (K, J,E,T,S,PT100,Cu100,Cu50,It can switch in menu) Analog signals:0-5V,0-10V,1-5V,4-20mA |
Output type | SSR,Relay,0-10v,4-20mA |
Alarm | Max 2 alarms Such as upper limit alarm, lower limit alarm, upper and lower limit alarm, upper deviation alarm, lower deviation alarm, interval alarm, interval alarm (user can set) |
Operating environment | 0-50℃, No condesation, Humidity:<85% |
Detailed Images:
Tecspecs:
Type | CD102 |
Power Supply | AC220V / 24VDC / 380VAC |
Input | Multi-input – K (-50~+ 1300℃), E(0~800℃), Cu50(-50~+150℃),PT100(-200~+600) |
Output | Double output(relay and SSR) / 4~20mA / 0-10V |
Accuracy of Measurement | ±0.5% |
Outline Dimension | 48*48mm |
Install Dimension | 45*45mm |
Operating temperature | 0-50℃ |
Compensating error of cold side | ±2℃(the software corrects the data for 0-50℃ fluctuations in temperature ) |
Control Mode | Adopt industrial and PID Parameters of Control System, Temperature Control, responsible faster, Start modulation smaller, accuracy higher than troditionalPID |
Type | CD series Temperature Controller |
Panel size | CD101 48x48mm CD401 48x96mm CD701 72x72mm CD501 96x48mm CD901 96x96mm |
Power supply | 85~265VAC 50~60Hz or 24VDC |
Accuracy | ±0.5F.S |
Control method | PID Control (with auto-tuning) or Self-tuning, or ON/OFF |
Sampling period | 0.5s |
Input type | TC, RTD (K, J,E,T,S,PT100,Cu100,Cu50,It can switch in menu) Analog signals:0-5V,0-10V,1-5V,4-20mA |
Output type | SSR,Relay,0-10v,4-20mA |
Alarm | Max 2 alarms Such as upper limit alarm, lower limit alarm, upper and lower limit alarm, upper deviation alarm, lower deviation alarm, interval alarm, interval alarm (user can set) |
Operating environment | 0-50℃, No condesation, Humidity:<85% |
Ask a quote for the latest price and one of our team members will respond as soon as possible. Fields marked with * are required.