Warranty:1 year
Customized support:OEM, ODM, OBM
Place of Origin:Zhejiang, China
Brand Name:SIMATE
Model Number:XMTD-2202
Color:Choice
MOQ:50PCS
PAYMENT:Trade Assurance TT \ TT \ Transferwise
Weight:0.2
Product name:XMTD-2202 temperature Durable control instrument
Certification:Reach
port:ningbo
XM series temperature display controller, TD (TE) series temperature control indicator adjuster, high product quality, small size, light weight, beautiful appearance, instrument with thermocouple has cold end automatic compensation function, series product measurement range -200- 1800 ° C. Can be widely used in metallurgy, plastics, packaging, food, printing, printing and dyeing, chemical, tobacco, oven, air conditioning and refrigeration, can also be used for pressure, flow, liquid level and other parameters of the measurement and control. Special specifications can be produced according to custom requirements.
Measurement accuracy: ±0.5%F±1
Sampling rate: 2 times / sec
Adjustment mode: Intelligent PID regulation, according to different PID parameters can be composed of P (binary), PI, PD, PID regulation
Output mode(Customizable): relay contact AC220V / 5A, level signal 12V /20mA, zero crossing trigger thyristor, analog quantity can be customized
Alarm mode: upper limit (or upper deviation), lower limit (or lower deviation)
With manual control function, and manual automatic undisturbed switching
Power supply(Customizable): 220 VAC, ± 10% / 50-60Hz
Power consumption: ≤ 5W
Ambient temperature: 0-50℃
Project | Parameter |
Model | XMTD-2202 PT100 (0-400℃) XMTD-2202 CU50 (-49.9+149.9℃) |
Setting error | ≤±1.5% |
Predetermined area | 0~100 |
Display error | ≤±2.5% |
Backlash | ≤±0.75% |
Time ratio adjustment | 3% to 6% Cycle time 30±10s |
Output electric shock capacity | AC 220V3A (resistive) or 1A (inductive) |
Power supply | 220V±10% 50HZ |
Operating temperature | -10-50℃ |
Relative temperature | Non-corrosive gas occasions up to 85 ° C |
Model and size
Model | Panel size H*B | Housing size h*b*L | Opening size h*b |
XMTA-C0000 | 96*96 | 92*92*72 | (92+1)*(92+1) |
XMTD-C0000 | 72*72 | 68*68*92 | (68+1)*(68+1) |
XMTE-C0000 | 48*96 | 44*92*72 | (44+1)*(92+1) |
XMTF-C0000 | 96*48 | 92*44*72 | (92+1)*(44+1) |
XMTG-C0000 | 48*48 | 44*44*78 | (44+1)*(44+1) |
XMTH-C0000 | 80*160 | 80*160*78 | (75+1)*(152+1) |
XMT-C0000 | 160*80 | 160*80*78 | (152+1)*(75+1) |
Instrument model name XMTA-CBCD
Parameter | Project | |||
A instrument panel size | B output mode | C alarm mode | D input method | |
A 96*96 | 1. Contact on-off two-position adjustment | 0 no alarm function | 1. Thermocouples E, K, S, B | |
D 72*72 | 2. Contact opening and closing three-position adjustment | 1 upper limit alarm | 2. Thermal resistance pt100, cu50 | |
E 48*96 | 4. Contact on and off PID adjustment | 2 lower limit alarm | 3. Standard voltage | |
F 96*48 | 5. Solid state relay drive output | 3 upper limit deviation value alarm | 4. Standard current 0~10mA | |
G 48*48 | 6. SCR phase shift trigger signal output | 4 lower limit deviation alarm | 5. Standard current 4~20mA | |
H 80*160 | 7. Thyristor zero-crossing trigger signal output | 5 upper and lower limit deviation value alarm | 6. Huo type transmitter and other millivolt input | |
T 160*80 | 8. Three-phase thyristor zero-crossing trigger signal output | 6 upper and lower limit alarm | 7. Remote pressure resistance signal | |
9. Output current 0-10mA or 4-20mA |
Digital display temperature control instrument Digital displa
Project | Parameter |
Model | XMTD-2202 PT100 (0-400℃) XMTD-2202 CU50 (-49.9+149.9℃) |
Setting error | ≤±1.5% |
Predetermined area | 0~100 |
Display error | ≤±2.5% |
Backlash | ≤±0.75% |
Time ratio adjustment | 3% to 6% Cycle time 30±10s |
Output electric shock capacity | AC 220V3A (resistive) or 1A (inductive) |
Power supply | 220V±10% 50HZ |
Operating temperature | -10-50℃ |
Relative temperature | Non-corrosive gas occasions up to 85 ° C |
Model and size
Model | Panel size H*B | Housing size h*b*L | Opening size h*b |
XMTA-C0000 | 96*96 | 92*92*72 | (92+1)*(92+1) |
XMTD-C0000 | 72*72 | 68*68*92 | (68+1)*(68+1) |
XMTE-C0000 | 48*96 | 44*92*72 | (44+1)*(92+1) |
XMTF-C0000 | 96*48 | 92*44*72 | (92+1)*(44+1) |
XMTG-C0000 | 48*48 | 44*44*78 | (44+1)*(44+1) |
XMTH-C0000 | 80*160 | 80*160*78 | (75+1)*(152+1) |
XMT-C0000 | 160*80 | 160*80*78 | (152+1)*(75+1) |
Instrument model name XMTA-CBCD
Parameter | Project | |||
A instrument panel size | B output mode | C alarm mode | D input method | |
A 96*96 | 1. Contact on-off two-position adjustment | 0 no alarm function | 1. Thermocouples E, K, S, B | |
D 72*72 | 2. Contact opening and closing three-position adjustment | 1 upper limit alarm | 2. Thermal resistance pt100, cu50 | |
E 48*96 | 4. Contact on and off PID adjustment | 2 lower limit alarm | 3. Standard voltage | |
F 96*48 | 5. Solid state relay drive output | 3 upper limit deviation value alarm | 4. Standard current 0~10mA | |
G 48*48 | 6. SCR phase shift trigger signal output | 4 lower limit deviation alarm | 5. Standard current 4~20mA | |
H 80*160 | 7. Thyristor zero-crossing trigger signal output | 5 upper and lower limit deviation value alarm | 6. Huo type transmitter and other millivolt input | |
T 160*80 | 8. Three-phase thyristor zero-crossing trigger signal output | 6 upper and lower limit alarm | 7. Remote pressure resistance signal | |
9. Output current 0-10mA or 4-20mA |
Ask a quote for the latest price and one of our team members will respond as soon as possible. Fields marked with * are required.